100%
fresh outside air is cooled
& washed through filter pads
Oxygen Rich Fresh Air
delivered to you
Dust and Pollen filtered
out. Fresh clean cool air
All 100% fresh outside air
Kozy cools to natures
limits
On warm day cooling may be
9C°/ 48°F
Hotter the day better it
works- 16C° / 62°F
Comfort is improved with air
movement- not stuffy & stale
Creates the right humidity
for human comfort
Adjustable air quantities to
suit all weather conditions
Less than 1/2 the cost of
refrigerated air
conditioning
Less than 1/3 the cost of
refrigerated air
conditioning to run
Evaporative cooling is the process of actually
reducing air temperature by the evaporation of
water in the air stream. The best
performing systems draw incoming air through a
wetted pad at the inlet of the ventilation
system. As air passes across the great
amount of surface area within the pad, BTUs of
heat are removed from the air, lowering the air
temperature. The more water is evaporated,
the greater the temperature reduction.
Also, the drier the air at low relative
humidity, the greater the ability of evaporation
to take place. During the hottest
time of the day, when cooling is needed,
generally the humidity will be low, and the air
will be cooled with our Atlantis SolarŽ Kozy
Coolers .
Temperature Humidity Index:
The chart below
shows the temperature of Atlantis
Solar's Kozy Air Cooled air for your
given ambient temperature and humidity.
Relative Humidity %
Celsius
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
23.9
11.1
11.7
12.8
13.3
14.4
15.0
15.6
16.7
17.2
17.8
18.9
19.9
20.0
20.6
21.0
21.7
25.6
11.7
12.7
13.9
14.4
15.6
16.1
17.2
17.8
18.3
19.4
20.0
20.6
21.1
22.2
22.8
23.3
27.2
12.8
13.9
15.0
15.6
16.7
17.8
18.3
19.4
20.0
20.6
21.7
22.2
22.8
23.3
24.4
25.0
28.9
13.9
15.0
16.1
17.1
17.8
18.9
19.4
20.6
21.1
22.2
22.8
23.9
24.4
25.0
25.6
26.7
30.6
15.0
16.1
17.2
18.3
18.9
20.0
21.1
21.7
22.8
23.3
24.4
25.0
26.1
26.7
27.2
27.8
32.2
15.6
17.2
18.3
19.4
20.6
21.1
22.2
23.3
23.9
25.0
25.6
26.7
27.2
28.3
28.9
29.4
33.9
16.7
17.8
19.4
20.6
21.1
22.8
23.3
24.4
25.6
26.7
27.2
28.3
28.9
29.4
30.6
31.1
35.6
17.8
19.4
20.6
22.2
23.3
24.4
25.6
26.7
27.8
28.9
30.0
30.6
31.7
32.2
33.3
33.9
37.2
18.3
20.6
21.1
22.8
23.9
25.0
26.1
27.2
28.3
29.4
30.0
31.1
31.7
32.8
33.3
34.4
38.9
19.4
21.1
22.2
23.9
25.0
26.1
27.2
28.3
29.4
30.6
31.7
32.8
33.3
34.4
35.0
36.1
40.6
21.2
21.7
23.3
25.0
26.1
27.8
28.9
30.0
31.1
32.2
33.3
33.9
35.0
36.1
36.7
37.8
42.2
21.1
22.8
24.4
26.1
27.2
28.9
30.0
31.1
32.2
33.3
34.4
35.6
36.7
37.8
38.3
38.9
43.9
22.2
23.9
25.6
27.2
28.9
39.0
31.7
32.8
33.9
36.1
35.0
36.1
37.8
38.9
39.4
40.6
45.6
22.8
25.0
26.7
28.3
30.0
31.1
32.8
33.9
35.0
36.7
37.8
38.3
39.4
40.0
41.1
42.2
47.2
23.9
25.6
27.8
29.4
31.1
32.8
33.9
35.6
36.7
37.8
38.9
40.0
40.6
41.7
42.8
43.3
48.9
24.4
26.7
28.9
30.6
32.2
33.9
35.6
36.7
37.8
38.9
40.0
42.2
42.8
43.4
44.4
45.0
Example : Inlet Air Temperature of
32.2° and humidity 35% results in
Kozy cool air output of temperature
22.2°
Relative Humidity %
Fahrenheit
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
75
52
53
55
56
58
59
60
62
63
64
66
67
68
69
70
71
78
53
55
57
58
60
61
63
64
65
67
68
69
70
72
73
74
81
55
57
59
60
62
64
65
67
68
69
71
72
73
74
76
77
84
57
59
61
63
64
66
67
69
70
72
73
75
76
77
78
80
87
59
61
63
65
66
68
70
71
73
74
76
77
79
80
81
82
90
60
63
65
67
69
70
72
74
75
77
78
80
81
83
84
85
93
62
64
67
69
71
73
74
76
78
80
81
83
84
85
87
88
96
64
67
69
72
74
76
78
80
82
84
86
87
89
90
92
93
99
65
68
70
73
75
77
79
81
83
85
86
88
89
91
92
94
102
67
70
72
75
77
79
81
83
85
87
89
91
92
94
95
97
105
68
71
74
77
79
82
84
86
88
90
92
93
95
97
98
100
108
70
73
76
79
81
84
86
88
90
92
94
96
98
100
101
102
111
72
75
78
81
84
86
89
91
93
95
97
99
100
102
103
105
114
73
77
80
83
86
88
91
93
95
98
100
101
103
104
106
108
117
75
78
82
85
88
91
93
96
98
100
102
014
105
107
109
110
120
76
80
84
87
90
93
96
98
100
102
104
109
108
110
112
113
Example : Inlet Air Temperature
of 96° and relative humidity 35%
results in Kozy cool air output
of temperature 78°